FRENIC-Lift series inverter is specially designed for operation of induction and permanent magnet
synchronous motors used in lift applications. Also induction motors without encoder (open loop) can be
controlled obtaining good performance and high positioning accuracy at stop.
The main characteristics of FRENIC-Lift are:
- Compact dimensions with high output power.
- Rescue operation with Battery or UPS with indication of recommended direction.
- Short floor operation with two different modes.
- 200% overload for 10 seconds.
- Communication protocols DCP 3 or CANopen integrated.
- Modbus RTU Protocol is integrated as standard.
- Incremental encoder input (12 V or 15 V / Open Collector).
- Optional cards for different encoder types (Line Driver, EnDat 2.1, SinCos...).
- Pole tuning and Auto tuning without removing the ropes (load).
- Multifunctional, detachable keypad.
- Braking transistor is integrated in all capacities.
- Operation of Induction motor without encoder (open loop) is possible.
Product infromation
Optimum Exclusive Design for Passenger Elevators
- A braking circuit is built in the AC Drives of all the capacities.
- Built-in PG feedback circuit is standard equipment.
- An optional keypad is available.
Higher Performance
- Overload capacity: 200% for 10s*1)
- Current response (ACR):500Hz
- Reduction of torque ripple realizes low vibration.
- Reduced roll-back during starting up.
*1) Except for 200 V / 22 kW and 400 V / 30 kW
High performance vector control
- Current response (ACR): 500Hz
- Speed control accuracy: ±0.01%
High overload capacity
200% of rated current for 10s*2)
(Overload begins from 80% continuous operation with a carrier frequency of 10kHz.)
*2) Except for 200 V / 22 kW and 400 V / 30 kW
IM/PMSM common drive
A single AC Drive can control an induction motor (open/closed loop control) and a synchronous motor (the optional PG interface card is required).
Model variations
FRENIC-Lift AC Drives are available in a series with capacities ranging from 4.0 to 45kW for three-phase 400V model.
5.5 to 22kW for three-phase 200V model.
2.2kW for single-phase 200V model.
Applicable to the feedbacks from various pulse generators
- Applicable to the inputs by open collector/complementary output as a standard specification (Encoder power supply is switchable between +12V and +15V.)
- Applicable to the inputs from the 5V line driver as an option
- Applicable to Sin/Cos, Serial interface (EnDat2.1) and Parallel interface (4-bit gray code, UVM 3-bit code)
Maintenance functions/Long life design
- DC bus capacitor life: 7 years
- Electrolytic capacitor life on the printed circuit boards: 7 years
- Cooling fan life: 5 years
- Life warning signal
- Recording and display of cumulative operating time
- Recording and display of cumulative operations
Globalization
- Safety standards
EN61800-5-1:2003,
EN954-1 Category3
- Sink/source switchable
- RS-485 communications (Modbus RTU) is adopted as standard equipment.
- CAN Bus is adopted as standard equipment.